A clean room is a space where the concentration of particles, microbes, and other contaminants is precisely regulated.
In the case of batteries there are a number of levels of cleanliness used depending on the material, component and manufacturing stage.
Clean rooms are classified according to the number and size of particles permitted per volume of air.
Clean rooms for battery manufacturing usually use the following classes of cleanness ISO 8, ISO7, and ISO6 per ISO 14644-1 standard or equivalent classes 100,000; 10,000; and 1,000 per FS209E standard. These classes belong to the middle class of cleanliness.
| Operation | ISO Class | Federal Standard 209E |
|---|---|---|
| Electrode Coating | 5 | 100 |
| Cell Assembly | 5 or 6 | 100 to 1,000 |
| Module Assembly | 7 or 8 | 10,000 to 100,000 |
| Pack Assembly | 7 or 8 | 10,000 to 100,000 |