Internal Resistance: DCIR and ACIR

Internal Resistance: DCIR and ACIR:- Let’s take a tiny step and understand how IR is measured in the first place.

How are resistances measured? A small current is injected into the component and voltage is measured across it and then resistance is calculated by R=V/I; yes! This is how a multimeter does its’ job; it’s not rocket science.

There are two different approaches followed in the battery industry to measure the internal resistance of a cell.

  • DCIR (Direct Current Internal Resistance)
  • ACIR (Alternating Current Internal Resistance)

DCIR measurement

A short pulse of high current is applied to the cell; the voltages and currents are measured before and after the pulse and then ohm’s law (I = V/R) is applied to get the result.

There are a number of phenomena contributing to the voltage drop, governed by their respective timescales:

  1. the instantaneous voltage drop is due to the pure Ohmic resistance R0 which comprises all electronic resistances and the bulk electrolyte ionic resistance of the battery
  2. the voltage drop within the first few seconds is due to the battery’s double layer capacitance and charge transfer resistance RCT which is attributed to the charge transfer reaction at the electrode/electrolyte interface
  3. the shallow, linear (or close to linear) voltage drop is due to polarisation resistance Rp which accounts for ionic difusion in the solid phase and is usually considered to be the rate determining step for Li ion batteries.

Barai, A., Uddin, K., Widanage, W.D. et al. A study of the influence of measurement timescale on internal resistance characterisation methodologies for lithium-ion cells. Sci Rep 8, 21 (2018)

cell voltage response to a current pulse

The formula for DCIR measurement is,

DCIR = (V0 – V2) / (I2 – I0) = ΔV / ΔI

There are standards set by the regulatory body, which should be followed while measuring the DCIR of a cell. These standards are set for universality and apple-to-apple comparison. I will write about a few of the widely used ones.

  • IEC 61960 

In this standard, a discharge pulse of 0.2C is given for 10 seconds and V1 and I1 values are measured. Then, another discharge pulse of 1C is given for 1 second and V2 and I2 values are measured. Then, DCIR is calculated with the above-mentioned formula.

Then, DCIR is calculated by

DCIR = (V1 – V2) / (I2 – I1)

  • ISO 12405

In this standard; first, a discharge pulse of 1C is given for 18 seconds, then discharge at 0.75C for another 102 seconds and measure V1 and I1 values. Then, let the battery rest for 40 seconds and record V2 and I2 values.

Then, a charge pulse of 0.75C for 20 seconds is given and V3 and I3 values are recorded. Finally, rest the battery for 40 seconds and measure V4 and I4 values.

Then, DCIR is calculated by

DCIR (Discharge) = (V2 – V1) / (I1)

DCIR (Charge) = (V3 – V4) / (I3)

ACIR measurement

As the name suggests, ACIR means Alternating Current Internal Resistance. An alternating current of 100mA 1000 Hz is applied to the cell via ACIR measurement equipment. The working principle of this equipment is; applying the Iac and then measuring Vac. Then

Impedance Z = Vac / Iac

When measuring the impedance, there will be a phase shift. So, only the Real part is considered to measure the internal resistance ignoring the reactance part. ACIR gives Rint only (Refer to figure 1).

ACIR = Re (Vac / Iac)

You can calculate the ACIR with the above formula. Beware, it’s complex!

Note: The Internal Resistance mentioned in the cells’ datasheet is ACIR.

A single-frequency ACIR reading is really just one point taken from a much wider picture. Sweeping the AC stimulus across a range of frequencies instead of testing at 1000 Hz alone is the basis of Electrochemical Impedance Spectroscopy (EIS), which can separate out the ohmic, charge-transfer and diffusion contributions to a cell’s resistance rather than lumping them into one number.

DCIR vs ACIR

The rule of thumb is that ACIR is approximately 70% of the DCIR value.

plot of cell ACIR vs DCIR from the cell database
ACIR vs DCIR
ACIR plotted versus DCIR on a log-log scale
ACIR vs DCIR (log-log scale)

Why do all this hassle?

To sort cells and bin them to make a high-quality battery pack.

A stringent procedure has to be followed to make battery packs better and sorting cells’ IR is one of them.

Imagine a battery pack with cells randomly selected and put together. Every cell will have a different IR and hence a different current distribution which leads to different temperature distributions of the pack. This is a clear recipe for disaster and has to be avoided at any cost.

ACIR or DCIR for sorting?

You can follow any one of the above procedures to sort cells. Since the procedure is the same for all the cells, thus sorting will be fair.

I would highly suggest going with ACIR as opposed to DCIR, as it slightly resembles real-life current excitation of a cell, especially in electric vehicles.


cell voltage response to a current pulse

DCIR of a Cell

The DCIR of a cell is the Direct Current Internal Resistance. This is the resistance in charge and discharge to a direct current demand applied across the terminals.

See also: Resistance, Pack Internal Resistance, HPPC Test Procedure, Relationship Between DCIR and Peak Discharge C-Rate in Lithium-Ion Cells