The GB 38031 page sets out what the 2025 edition of China’s traction battery safety standard requires. This post asks two different questions: how would an engineering team actually go about passing it, and what have the big battery makers said publicly about where they stand? It deliberately does not repeat the test descriptions, so read that page first if you want the full test list.
What changed, in one paragraph
The 2020 edition gave occupants a warning window: a pack in thermal runaway could burn, provided it stayed clear of fire and explosion for five minutes. The 2025 edition, in force for new type approvals from 1 July 2026 and for existing approved vehicles from 1 July 2027, asks for no fire and no explosion across a two-hour observation after runaway is triggered, plus two further tests: a bottom impact and a short circuit after 300 fast-charge cycles.[1][3] The vehicle-level companion standard GB 18384-2025 changes the high-voltage disconnect requirement as well.[3]
Part 1: how a team could approach compliance
None of what follows is a description of any one company’s design. It is a way of mapping each test onto the engineering levers that are generally available, so treat it as a starting framework.
The two-hour thermal propagation test
The trigger cell goes into runaway, and the pack then has to keep the consequences inside for two hours. In the AVL description the test is run with a cabin-smoke criterion and an alarm that must come within five minutes of runaway, with temperature monitoring points staying at or below 60 °C.[1] That makes it a system problem with five levers working together:
- Heat path between cells. Barrier thickness, material and compressibility decide how much of the trigger cell’s heat reaches its neighbours. Anything that survives long enough for the neighbour to cool below its onset temperature breaks the chain. The physics is covered on Thermal Propagation and Physics of Thermal Runaway.
- Spacing and heat sinking. Gaps and cold plates buy time but cost energy density, which is why cell-to-pack designs make the barrier question harder, not easier. See CATL Qilin CTP 3.0 for one high-density example.
- Venting direction and gas management. Ejected gas and particulates are what turn a single-cell event into a pack fire, because hot gas can ignite or conduct. Directing vents away from neighbours, towards a defined exhaust path, and cooling the gas before it leaves the pack are all design choices. CATL’s Dual Vent Prismatic Cell and Quantitative Battery Venting give a feel for the numbers.
- Chemistry. LFP releases less heat and starts runaway later than NMC, so the barrier and venting task is easier. NMC packs can still be made compliant, but the margins are thinner and the manufacturer’s own test report matters more.
- Detection and BMS response. The alarm requirement means the pack must recognise an event quickly using gas, pressure, temperature or voltage signals, and then act on it. Options are discussed on Early and Passive Thermal Runaway Detection.
Bottom impact
A 30 mm impactor strikes the underside of the pack three times at 150 J, with the pack charged to at least 95% state of charge if it is externally chargeable.[1][6] The pack must not leak, rupture, burn or explode, and insulation resistance has to hold. The design levers are underbody shield stiffness and energy absorption, the crush space between shield and cells, where the pack sits relative to ground clearance, and how the cooling plate (often the bottom layer) behaves under local deformation, because a punctured coolant channel next to live cells is a second failure mode.
External short circuit after 300 fast-charge cycles
The cycling profile is 20 to 80% in about 15 minutes or less, repeated 300 times, followed by a ten-minute short circuit through a resistance of 5 mΩ or less.[1] The point is that a cell with lithium plating or other fast-charge damage may fail differently from a fresh one. Engineering responses are on the cell side (anode design and electrolyte to limit plating, see Lithium Plating), on the charge-control side (temperature-dependent current limits), and on the protection side (fuse and contactor coordination so the short is interrupted before heat builds).
Part 2: who has said what
The statements below are what each company, or a named representative, has said in public, as reported by the sources in the references. They are not independent verifications, and the test reports themselves have not been published in any of the cases I found.
- CATL. On 29 April 2025 CATL announced that its Qilin battery, an NMC product, had passed GB 38031-2025 testing carried out by the China Automotive Technology and Research Center.[2] In May 2025 it also said that several mass-produced products, including Qilin, Shenxing and Freevoy, had received GB 38031-2025 test reports; the reporting I found does not say what those reports covered.[4] A CATL executive quoted by China Auto News says its first-generation no-propagation battery was in mass production in 2020.[3]
- BYD. BYD’s public relations general manager announced that the Blade Battery and the second-generation Flash Charge Blade Battery had passed all items of the new standard, with certification issued by the same research centre.[5] The BYD Blade 2.0 comparison covers the cell differences.
- EVE Energy. A deputy general manager for commercial vehicle battery applications is quoted as saying EVE’s ternary and LFP systems reached “no fire, no explosion” in 2022.[3] That is a statement about internal results, not a certification against the 2025 text.
- CALB, Gotion, SVOLT, Sunwoda. I did not find public statements from these four tied to GB 38031-2025 in the sources I could open, so I am not making any claim about them.
Vehicle makers: who says they comply
The claims above come from cell and battery makers. Several vehicle makers have also said they are covered, and the strength of the evidence varies a great deal. Leapmotor is the clearest case: a May 2025 report says its cell-to-chassis battery was in the first batch to pass, with testing by the CATARC New Energy Inspection Center that included bottom impact, thermal stability and water immersion.[7] BYD says it holds a full test report for its Blade battery range, quotes a warning time of more than 18 minutes against the five-minute requirement, and a later report adds BYD’s own claims for the second-generation Blade (more than 24 hours of containment and underbody impact at ten times the requirement). The copy I found does not name the issuing laboratory.[8][9] Geely says it completed all testing in May 2025 across its range and helped draft the bottom-impact test, and Zeekr says its design already meets or exceeds the standard without a cost increase; no laboratory is named.[10]
Chery said on 2 July 2026 that its whole range with Rhino batteries meets the standard, backed by a lifetime battery warranty for the first private owner and a replacement car if a thermal runaway not caused by a person occurs, but it gave no certificate or design detail.[11] XPeng and Great Wall were reported in May 2025 as saying their in-use batteries passed inspection against the new standard, and the same aggregator lists NIO, Li Auto, Xiaomi, Deepal and Voyah as first-batch, though I could only trace that to one secondary source.[12] I found nothing from Tesla China, Volkswagen, Mercedes, BMW, Honda or the Huawei-linked brands, which does not mean nothing exists. A 36Kr report counts 16 makers claiming compliance by the end of June 2026.[9] I did not find an MIIT catalogue entry or certificate number for any model, and only Leapmotor’s claim names a test body. The public statements say little about how: BYD points to LFP chemistry and the blade cell format, Leapmotor to chassis integration, Geely to its role in the test drafting.
Cost impact
China Auto News, citing an unnamed market research firm, puts the increase in battery system cost at 15 to 20%, which one outlet converts to roughly 3,000 to 5,000 yuan per pack.[3] Treat that as an indicative figure from a single report. The same source says firms that planned early face small impact, while smaller firms and low-end models face more pressure, and that LFP’s thermal stability should keep its cost increase lower, which is the writer’s view and not a sourced estimate.
I could not find a bottom-up cost model for the 2025 standard from an analyst or consultancy, so every figure traces back to a handful of estimates. Dollar figures use 6.6973 yuan per US dollar, the rate quoted for 9 October 2026.[15]
| Estimate | Yuan | US dollars | Basis and source |
|---|---|---|---|
| Rise in battery system cost | +15% to 20% | Percentage, no conversion | Named analyst, no method given.[13] The same range is attributed to unnamed “industry calculations” elsewhere.[9] |
| Per pack | 3,000 to 5,000 yuan | about $450 to $750 | Reached CnEVPost through China Auto News and an unnamed research firm.[3] Appears to be the percentage applied to a typical pack, but no source states that. |
| Per vehicle (manufacturing cost) | 4,000 to 6,500 yuan | about $600 to $950 | Attributed to the same analyst by Tencent News.[14] |
| Ceramic-coated separator upgrade | +20% to 30% on separator cost, about +1.2% to 2.4% on pack cost | Percentage, no conversion | Anonymous supplier insider relayed in a May 2025 article.[12] |
Treat the first three rows as one estimate repeated rather than independent confirmation: the per-vehicle range is the per-pack range plus whatever vehicle-level changes follow. Company comments pull in different directions. Leapmotor’s senior vice president Cao Li said it would be wrong to claim costs did not rise, pointing to its redesign around ten layers of physical protection, while founder Zhu Jiangming blamed raw-material prices rather than the standard; Zeekr says its prices will not rise.[16] A BloombergNEF analyst quoted by 21jingji expected a premium that is not in the materials themselves and no significant rise in purchase cost.[17] I found no per-kWh figure and no cost breakdown for barriers, venting, sensing or underbody protection, apart from the anonymous separator estimate.
What third-party analysis says about the test procedure
I found no procedural analysis from an independent test house or certifier: searches for TUV, UL Solutions, DEKRA, Intertek, SGS, CATARC and Exponent returned nothing detailed. The fullest accounts come from consultancies and vendors who sell related services, so read them with that in mind. The AVL and H&Z whitepaper lists three ways to start the runaway (external heating, nail penetration and internal heating) and suggests they are tried in turn until one works. It leaves open the order, how the trigger cell is chosen, how the monitoring points are defined and whether two hours is a minimum.[1] IDTechEx describes the same trigger set and calls the two-hour requirement a major challenge that is easier for LFP than for NMC.[18]
The alarm and smoke criteria are also easy to misread. In the English translation I found, the alarm must sound no later than five minutes after runaway begins, and no smoke may endanger the passenger compartment before the alarm or in the five minutes after it, which matches AVL’s description of a window either side of the alarm.[19] That reverses the 2020 framing, where the warning had to come before a hazard. The translation is not the official text, so check the clauses yourself.
Independent trigger-method research suggests why these open details matter. In one multi-pouch-cell test bench, nail penetration parallel to the electrode layers produced a significant reaction while penetration at right angles did not, and two nominally identical runs propagated in about 34 and 32 seconds (a sample of two).[20] A national-laboratory comparison found that an internal-short device was more severe for a single cell, while external heating gave hotter neighbours in a multi-cell test, so the trigger choice alone changed which looked worse.[21] Another study found nail triggering gave repeatable trigger-cell curves, yet 56% of 32 tests propagated, with outliers from cell movement.[22] My reading is that a design should be characterised against more than one trigger and with margin, but none of these papers mention GB 38031-2025, and I found no clause-by-clause comparison with GTR 20 or R100.
University and academic research
I found no paper that analyses the 2025 requirements directly. The closest confirmed link is a 2024 paper from a Luoyang battery maker and Henan University of Science and Technology whose reference list cites the 2020 edition.[23] What exists is related work, and I could read only abstracts for most of it.
On barriers, that Henan study found 0.7 mm and 1.2 mm aerogel pads slowed or stopped propagation in large-format LFP modules.[23] A USTC and China Southern Power Grid study on 280 Ah LFP modules found 1 mm and 2 mm glass-fibre aerogel stopped propagation in an alternating-barrier layout, while 2 mm ceramic fibre felt only delayed it, and a barrier between every pair of cells cut the temperature rise further at the cost of space.[24] A Tsinghua group reported a 1 mm phase-change and silica nanofibre firewall that stopped propagation between fully charged 50 Ah cells.[25] Tsinghua work on stacked storage cells also shows that ignition of vented gas is a heat path separate from conduction, with roughly 47.5% of the heat reaching the upper cells through the bottom and 52.5% through the sides, which matters for a no-fire criterion more than for a no-propagation one.[26] See our pages on thermal barrier materials and propagation resistance testing.
Evidence on the bottom-impact test is thin. A Beijing Institute of Technology study validated a finite-element model of a ball strike against quasi-static tests, but I could not confirm it used the 30 mm and 150 J condition.[27] For the post-fast-charge short circuit, a UCL study of 21700 cells found that sub-zero cycling caused plating, collapse of the jelly roll and an earlier start of self-heating (about 114 °C against about 160 °C), though similar runaway onset and more ejected material. That is cold cycling, not the fast-charge profile in the standard, so it supports the plating concern without testing it.[28]
Sensing: what is used and what is being considered
The standard sets a ceiling on alarm latency (five minutes after runaway) rather than demanding detection before runaway, so earlier detection is a design choice that buys margin and mitigation time.[19] I could not read the clause on data recording, so I do not know whether it mandates a particular signal or interface. The minimum is therefore a BMS that spots the event from cell voltage and temperature quickly enough. One 2026 paper using voltage and temperature from a 138.5 Ah LFP pack reported an average warning lead of about 115 seconds, and about 323 seconds before runaway in a nail test, but on a single self-built dataset.[29] See also our pages on BMS sensors and early and passive thermal runaway detection.
Component suppliers are pushing faster, redundant sensing. Pressure sensors are offered by Honeywell and NXP (the NXP family has a built-in microcontroller with configurable thresholds), and a Churod product claims a 10 Hz output.[30][31][32] Gas sensing is the other main route: Sensirion launched an automotive-qualified hydrogen sensor in June 2026, and Amphenol’s TRDU module combines hydrogen, carbon monoxide, hydrocarbon, pressure, temperature and humidity sensing with a claimed response under a second.[33][34] Honeywell also lists electrolyte-vapour and particulate sensors.[30] A review of semiconductor gas sensors concludes that gas signatures can appear before voltage or temperature anomalies and differ between LFP and NCM811, with low-concentration sensitivity still an open problem.[35] KAUST researchers have shown laser detection of hydrogen fluoride from vented cells in the lab.[36] The most striking research figure is an in-cell fibre Bragg grating that gave strain-based warning up to 18.8 minutes before voltage-based signals, in a single cell.[37]
Almost all the supplier claims are marketing: I found no published pack-level detection-time data for the commercial pressure, gas or particulate sensors. One trade article lists the trade-offs: gas sensors draw more power and raise lifetime questions, temperature sensors respond slowly at distant cells, and pressure switches can give false alarms from altitude changes or tunnels.[32] I found nothing usable on acoustic, impedance or expansion-force sensing, or on sensor details from BYD, Huawei or NIO.
What other regulators are doing
I found no regulator or standards body that has said it will adopt GB 38031-2025. The route by which it could shape others is the UN process. UN Regulation 100, in its 05 series (in force since 26 September 2025), already has a time-limited propagation rule: after a single-cell runaway there must be no fire, explosion or smoke into the passenger compartment within five minutes of the warning, and no propagation within the pack for two hours, shown by test or by risk analysis. The transition dates in the source I used are inconsistent, so check UNECE.[38] A proposed amendment to UN GTR 20 on propagation was tabled at GRSP’s December 2025 session with China among the co-sponsors, alongside Canada, the EU, France, Germany, Japan, Korea, the Netherlands, the UK and the USA, and the EU is leading a further phase covering a wider propagation scope.[39] AVL’s whitepaper speculates that elements of the Chinese text could be proposed for a later R100 revision, but I found no UN document that cites it.[1]
In the United States, the FMVSS 305a final rule of December 2024 dropped the proposed warning test and instead requires documentation of the warning system and of propagation risk mitigation, with compliance from 1 September 2027 for lighter vehicles; I found no sign of a move to a propagation test.[40] In the EU, the Battery Regulation’s propagation test applies to stationary storage, and road vehicles are covered through R100.[41] A Korean press report from April 2025 said Korea had no observation period at the time and that experts saw China as more active, with Korea waiting for the UN.[42] India’s AIS-156 for L-category vehicles already uses a no-fire, no-explosion criterion with a warning, but I could not find propagation detail for AIS-038 or any reference to China.[43] I found nothing from Japan. A draft revision of ISO 6469-1 is out for comment on assessing propagation mitigation.[44] My reading is that most regulators will follow the UN rather than China directly, so R100 05 and GTR 20 remain the baseline for global platforms, while makers selling into China will meet the stricter outcome anyway. Several of these sources were read through summaries, so confirm against the primary texts before relying on a date or figure.
How it compares
| Aspect | GB 38031-2020 | GB 38031-2025 |
|---|---|---|
| Thermal propagation outcome | No fire or explosion for 5 minutes after runaway | No fire or explosion for 2 hours, alarm within 5 minutes |
| Bottom impact test | Not present | 150 J, 30 mm impactor, three impacts |
| Post fast-charge short circuit | Not present | After 300 fast-charge cycles |
| Effective | 1 January 2021 | 1 July 2026 (new types), 1 July 2027 (existing) |
References
- AVL, “Regulation GB 38031-2025” whitepaper, October 2025
- TechNode, “CATL says it is first to meet China’s new battery safety standards”, 6 May 2025
- CnEVPost, “China’s toughest battery safety rules take effect in July”, 30 June 2026
- Vozpopuli, report on CATL and BYD GB 38031-2025 claims
- CnEVHome, “BYD’s Blade Battery / Flash Charge Blade Battery pass new national standard ahead of schedule”, 27 May 2025
- H&Z Group, “GB 38031 battery safety EV regulation”
- Tencent News, Leapmotor CTC battery and CATARC testing, 9 May 2025
- WCEVCAR, BYD Blade battery and the new standard, May 2025
- 36Kr, GB 38031-2025 cost and manufacturer readiness, 13 July 2026
- Tencent News, Geely announcement on the new standard, 1 July 2026
- CarNewsChina, Chery lifetime battery warranty, 2 July 2026
- Tencent News, analysis of cost and supplier readiness, 27 May 2025
- Xinhua, coverage quoting Zhong Shihu on the cost impact, 14 July 2026
- Tencent News, cost impact of the new battery standard, 2 July 2026
- Pound Sterling Live, USD to CNY history for 2026 (rate for 9 October 2026)
- Tencent News (Dongjianshang), commentary on vehicle maker cost and pricing responses, 1 July 2026
- 21st Century Business Herald, BloombergNEF analyst comment on cost, 16 June 2025
- IDTechEx (J. Edmondson), “New Standards put China in the Lead for the Safest and Largest EV Market”, 24 April 2025
- ChineseStandard.net, English machine translation of GB 38031-2025 (not the official text)
- Mulder, Schoberl and Birke, thermal propagation test bench with a multi pouch cell setup, Batteries 9(9):447, 2023
- Mallarapu et al., effects of trigger method on fire propagation, Journal of the Electrochemical Society 171:040514, 2024
- Fransson et al., nail-triggered propagation tests, Journal of Power Sources 617:234916, 2024
- Cao et al., aerogel pads in large-format LFP modules, Energy Storage Science and Technology 13(7):2462, 2024
- Lei et al., barrier materials in 280 Ah LFP modules, Energy Storage Science and Technology 13(2):495, 2024
- Li et al. (Tsinghua), ultrathin thermal-responsive firewalls, Energy Storage Materials 40:329, 2021
- Xu et al. (Tsinghua), flame spread in stacked 100 Ah LFP cells, Energy Storage Science and Technology 14(9):3552, 2025
- Yan et al., simulation of pack bottom ball strike (LS-DYNA), Mechanisms and Machine Science 151, 2024
- Kirchner-Burles et al. (UCL), sub-zero cycling and abuse behaviour of 21700 cells, Journal of Power Sources 660:238565, 2025
- MSTA-Net thermal runaway early warning from voltage and temperature, Sensors 26(10):3083, 2026
- Honeywell, battery safety sensors product page
- NXP, battery pressure monitoring sensors product page
- GlobalSpec Electronics360, thermal runaway sensor advances, 1 March 2025
- Sensirion, STC42A automotive hydrogen sensor announcement, 16 June 2026
- Mouser, Amphenol SGX Sensortech TRDU sensors
- Teng and Lv, review of semiconductor gas sensors for thermal runaway, Frontiers in Chemistry 13:1586903, 2025
- KAUST, laser-based HF gas detection for early battery failure, 13 May 2026
- Pan et al. (Beijing Institute of Technology), in-cell fibre Bragg grating early warning, Advanced Functional Materials 36, 2026
- Lovguiden, summary of the EU notice on UN Regulation 100 (05 series), 17 August 2026
- Global Auto Regulations, GRSP-78 agenda and documents (GTR 20 thermal propagation proposals)
- Federal Register, FMVSS No. 305a final rule, 20 December 2024
- Energy Storage Europe conference slides, the new EU Battery Regulation and safety, October 2025
- Asia Economy, Korean thermal runaway rules compared with China, 21 April 2025
- EVreporter, battery safety standards in India
- BSI Standards Development, ISO 6469-1 revision project