When One Cell Fails: What Its Neighbours Experience

When one cell goes into thermal runaway, whether you end up with a contained event or a pack fire depends on what its neighbours experience, thermally and electrically. This post sets out the heat paths that published test work identifies, what that work does and does not quantify, and the electrical effects, which get less attention. The failing cell itself is covered on What Happens if a Cell goes into Thermal Runaway? and the propagation mechanics on Thermal Propagation.

How heat gets from the failing cell to the next one

There are four routes, and their share changes with cell format, spacing and state of charge:

  1. Conduction through the cell cans, tabs and busbars
  2. Radiation across the gap
  3. Hot gas and ejected material leaving the vent
  4. Electrical heating in the neighbours when current is forced through them

NASA test work on 18650 cells names cell-to-cell conduction and electrical shorts as the main contributors and calls radiation a contributor but not the leading one.[1] A separate NASA presentation notes that vented effluent carries enough energy to promote propagation.[2] Work on 12 Ah NMC622 pouch cells adds that the swelling gas inside the pouch changes the heat path until the seam opens, and that outflowing gas becomes a significant transport route just before and during rapid runaway.[3]

Hand-drawn notebook sketch of two cells side by side showing four heat paths from the failing cell to its neighbour: conduction through cans, spacers, tabs and busbars; radiation across the gap; vented gas and ejected material; and current forced through the neighbour causing I squared R heating
The four routes by which heat and energy reach a neighbouring cell. A schematic sketch, not to scale; it does not show the relative size of each route.

Vent space above cells is critical, typically for 21700 cylindrical cells this is ~9-12mm to allow the gas to expand.

CATL with their prismatic cells have moved the vent path to the opposite side to the electrical connections to reduce the chance of vented gas and particulates creating an HV short.

Tesla use a barrier material that allows vent gases and particles to escape from the failing cell, but to protect neighbouring cells.

The same pouch study shows how much the barrier matters: with no barrier the neighbour reached runaway in about 18 s in the experiment, a 1 mm mica sheet at low compression stretched that to about 37 s, and the same sheet pressed at high force brought it back to about 17 s.[3] The barrier is only as good as its compression state.

Is there a single number for how much heat reaches a neighbour?

I looked for a published fraction of the failing cell’s heat that reaches its neighbour, and the sources above do not give one. They describe mechanisms and report propagation times for particular cells and barriers, but not a general share.[1][2][3] That is unsurprising: the share depends on which of the four routes are open, so it is a property of a specific cell format, spacing, barrier, compression and state of charge, not of the chemistry alone. Any percentage quoted for barrier performance should be traced back to the test that produced it before it is reused.

What can be done from first principles is to ask the inverse question: how much heat has to reach a neighbour to bring it to the temperature where it starts to self-heat? That is its mass times its specific heat times the temperature rise (see Specific Heat Capacity of Lithium Ion Cells):

Qneeded=mcpΔTQ_{\text{needed}} = m\,c_p\,\Delta T

As an illustration only, take a 2.6 Ah, 3.7 V 18650 cell, the type used in the NASA work,[1] with an assumed mass of 45 g and specific heat of 1 kJ/kg·K. Warming it by an assumed 100 K takes about 4.5 kJ. Its stored electrical energy is about 34.6 kJ, and in one calorimetry example for a different cell (2.4 Ah) the energy needed to take the failing cell to its peak temperature was about 42% of its stored energy.[2] If the same proportion applied here, roughly 14.5 kJ of heat would be released and the neighbour would need about 31% of it. The point is the sensitivity, not the answer: change the cell mass, the onset temperature or the state of charge and the required share moves a long way, which is another reason a single figure cannot be taken as general.

This post has been built based on the support of and sponsorship from: illumion, Custom Power, Quarto Technical Services, Eatron Technologies and About:Energy

The electrical side

Electrical effects start before the thermal ones reach the neighbour, and they depend on how the cells are connected:

  • Cells in parallel. A cell that develops an internal short becomes a load on every cell in its parallel group, and they discharge into it. That current heats the neighbours resistively and their own internal resistance. The Cell Internal Short Circuits page covers how the short forms, and Cells in Parallel covers the group behaviour. Cell-level fusing, where used, is meant to isolate the failing cell from the group.
  • Cells in series. A cell that shorts internally drops its voltage towards zero, which the BMS sees as a cell voltage collapse. A cell that goes open-circuit instead interrupts the whole string current. Either way the rest of the string sees a changed operating point at the moment it is also heating up.
  • Across strings. In packs with parallel strings, a failed string can pull current from the others through shared busbars; the Cross-String Current Sharing page describes the mechanism in normal operation.

The practical consequence is that thermal and electrical barriers have to be designed together. A barrier that delays conduction does nothing about a short that is driving current through the neighbour, and a fuse that isolates a cell does nothing about heat leaving through the case. Detection is the third piece: see Early and Passive Thermal Runaway Detection, and for how propagation resistance is measured, Passive Propagation Resistance (PPR) Test.

References

  1. E. Darcy, “Thermal Runaway Severity Reduction Assessment and Implementation: On LREBA and LPGT”, NASA Johnson Space Center, 2015 Space Power Workshop
  2. R. Button, NASA Engineering and Safety Center presentation, NASA Battery Workshop 2014
  3. N. Weber, S. Schuhmann, R. Löwe, J. Tübke, H. Nirschl, “On the effect of gas generation on heat transfer during thermal runaway of pouch cells”, 2024

See also: Thermal Runaway in High-Voltage Systems, Short Circuit, Cell Internal Short Circuit Device