Creepage and Clearance Calculator

A simple creepage and clearance calculator, providing indicative minimum distances based on IEC 60664-1:2020 and ISO 21498:2021 table lookups with linear interpolation. It does not replace formal insulation coordination analysis by a qualified engineer. Always verify against the applicable standard for your specific application and jurisdiction. BatteryDesign.net accepts no liability for design decisions made using this tool.

High-voltage circuits can arc or flash across a gap. Whether that discharge travels through the air or tracks along a surface depends on geometry, voltage, and environmental conditions. Two distinct minimum distances are therefore controlled in HV design.

Both are defined in IEC 60664-1, the primary insulation coordination standard for systems up to 1,000 V AC / 1,500 V DC. For automotive battery systems, ISO 21498-1 and the VDA LV 123 standard also reference these principles. The purpose is to prevent two distinct failure modes: electrical breakdown across an air gap (clearance violation) and surface tracking along insulation (creepage violation).

→ Creepage and Clearance

schematic of creepage and clearance in HV systems

Creepage — the shortest path between two conductors measured along the surface of an insulating material.

Clearance — the shortest path between two conductors measured through the air.

Worked Examples

StandardVoltagePDOVCMaterialAlt (m)Expected creepExpected clear
IEC 60664-1800 V DCPD 2OVC IIIIIa0 m6.30 mm6.0 kV impulse → 5.50 mm
IEC 60664-1800 V DCPD 2OVC IIIIIa3000 m6.30 mm5.50 × 1.235 = 6.79 mm
IEC 60664-1400 V ACPD 3OVC IIIIIIb0 m8.00 mm6.0 kV impulse → 5.50 mm
ISO 21498400 V DCPD 2OVC IIIIIa0 m4.00 mm4.0 kV impulse → 3.00 mm
IEC 60664-1800 V DCPD 2OVC III0 m4.00 mm (Reinf: 8.00)5.50 mm (Reinf: 11.00 mm)

Note on clearance for 800 V DC: 800 V sits in the 601–1000 V rated voltage bracket of IEC 60664-1 Table F.1. OVC II at that bracket gives a 6.0 kV rated impulse voltage, which requires 5.5 mm clearance (Table F.2, PD 2). This is higher than the 3.0 mm figure sometimes seen in automotive references, which use the mains supply voltage (e.g. 230 V AC → OVC II → 2.5 kV impulse) rather than the DC bus voltage to determine impulse level. This calculator applies Table F.1 to the working voltage entered, which is the correct approach for equipment rated at that voltage.

Appendix A  —  CTI Material Group Quick Reference

GroupCTI range (V)Typical materialsCommon automotive use
ICTI ≥ 600Glass, ceramic, PTFE, micaHV connectors, power electronics substrate
II400 ≤ CTI < 600Phenolic, some PA66 GFBMS connector housings
IIIa175 ≤ CTI < 400FR4 PCB, PP GF, PA6 GF, PBT GFPack busbars, module housings, PCBs
IIIb100 ≤ CTI < 174Unfilled PA, some polyesterAvoid in HV applications above 400 V

Appendix B  —  Overvoltage Category Quick Reference

OVCDescriptionAutomotive example
IProtected from mains transientsInternal low-voltage circuits behind DC-DC converter
IIEquipment connected to fixed installationTraction battery pack (BMS-protected, fused at PDU)
IIIFixed installation, special requirementsHigh-voltage PDU, main contactors, charging port
IVAt origin of installationVehicle inlet directly exposed to charger cable transients

See also: Insulation and Isolation, IEC 60112, Comparative Tracking Index