Megawatt Charging: What 1,000 kW and 10C Mean for Cell and Pack Design

BYD megawatt charger

Megawatt charging for passenger cars has moved from a slide-deck number to a product. BYD describes a platform that moves energy at 1,000 kW, and in March 2026 it said a second-generation Blade battery can take up to 1,500 kW at its newest chargers.[1] This post looks at what those numbers ask of the cell, the pack and the charger, rather than at the announcement itself. Everything quoted about BYD is a company claim; where the sources leave a figure out, the arithmetic below is ours and is labelled as such.

This post has been built based on the support of and sponsorship from: illumion, Custom Power, Quarto Technical Services, Eatron Technologies and About:Energy

What the headline numbers imply

Power is voltage times current, so 1,000 kW at 1,000 V means roughly 1,000 A. BYD’s earlier Super e-Platform is described as a 1,000 V, up to 1,000 A system.[1] For the second generation the sources give the peak power but not the voltage or current; if the voltage stayed near 1,000 V, 1,500 kW would need around 1,500 A. That is our inference, not a stated specification.

The quoted charge times convert into average C-rates. Going from 10% to 70% in five minutes is 60% of capacity in 1/12 of an hour, an average of about 7.2C. Going from 10% to 97% in nine minutes is about 5.8C on average.[1] The peak, at the start of the session, must be higher than either average, which is why a 10C figure is quoted for the cell.[2] For a 100 kWh pack, 10C is 1,000 kW, so the pack size and the charger rating are linked directly. A smaller pack at the same C-rate needs a lower-power charger, and a larger one needs more.

Cell design: plating and heat

At these rates the limiting problem inside the cell is usually lithium plating. When the negative electrode is pushed hard, the local potential of the graphite surface can drop below that of lithium metal, and lithium deposits on the surface instead of intercalating. The mechanisms are covered in our lithium plating page, and the gradients in the electrolyte that make it worse are explained in Concentration Polarization. Test evidence on how commercial cells actually behave is in Study of Lithium Plating in Commercial Cells. The usual design levers are thinner electrode coatings, more porous and better-wetted structures, lower-resistance electrolytes and operating the cell warm during the charge. BYD’s interview material says little about the cell internals, and the plating question is not addressed in the sources used here.[2]

Heat is the other constraint. Resistive heating scales with the square of current, so moving from 1,000 A to 1,500 A multiplies the I squared R loss by 2.25 for the same resistance. As an illustration only, a pack with a total series resistance of 1 milliohm dissipates about 1 kW at 1,000 A and about 2.25 kW at 1,500 A. BYD’s charging director calls heat the biggest problem during charging, and credits the Blade format’s cooling behaviour for allowing more energy to be injected without overheating.[2] Our Cell to Pack Fast Charging post covers how pack structure changes the heat path.

Pack and high-voltage hardware

Running at 1,000 V instead of 800 V keeps the current lower for a given power, which allows less copper in cables and busbars. BYD’s charging director makes that point directly, and says the company builds nearly all of the platform’s components in-house.[2] The trade-off is that every voltage-rated part, from contactors and fuses to connectors and busbars, needs a higher rating, and the insulation distances grow. The creepage and clearance page explains how the distances are chosen, and the Creepage and Clearance Calculator lets you see how they change as the working voltage moves from 800 V to 1,000 V. For the wider architecture trade-offs see 800V Architecture and Voltage Architecture.

Cables, connectors and the charger

In China, the Han L and Tang L are described as using two charging cables at once, with a port above each rear wheel. For Europe, a BYD representative said at IAA Mobility 2025 that a single cable would be enough to reach the 1,000 kW maximum on a standard CCS plug.[3] That depends on liquid cooling in the connector. BYD says it has concentrated on cooling the contact pins, which it identifies as the usual bottleneck, and that it may draw on the cooling approach used for heavy-vehicle megawatt charging.[2] Whether the connector is BYD’s own or a supplier’s part was not clear in the reporting.[3]

The grid side is handled with a buffer. According to the same interview, each Flash charging site includes a BYD battery that stores energy between sessions, so the site can draw roughly 50 to 200 kW from a standard 400 V AC supply and release it at megawatt rates. Buffer capacity and sizing were not disclosed.[2] This is the reason a very high charging power does not automatically require a new substation, although it does mean the charger is itself a battery system with its own thermal and safety design to consider.

What to take from this

A megawatt charge session is a system problem. The cell has to avoid plating at the peak current, the pack has to remove the heat, the high-voltage parts have to hold their insulation at 1,000 V, the connector has to shed its own heat, and the site needs a buffer to avoid overloading the grid. None of the sources used here give cell-level plating data or pack heat-rejection figures, so the engineering numbers above are inferences from the headline specifications. For earlier thinking on the same theme, see Charging at the Speed of a Petrol Pump, BYD Blade 2.0 compared to 1.0 and our Fast Charging hub.

References

  1. BYD launches game-changing new Blade battery with 5 minute charge time, The Driven, 6 March 2026
  2. The 10C Revolution: What goes behind BYD’s 1,000 kW Charging, EVreporter, interview with BYD Europe, March 2026
  3. BYD targets “Flash Charging” in Europe with a single cable, electrive, 12 September 2025

See also: Lithium Plating, 800V Architecture, Fast Charging, Creepage and Clearance Calculator, 10-80% Charge time is falling by 1.7 minutes a Year

Get the next teardown in your inbox

New teardowns, benchmarks and design data from BatteryDesign.net, free by email. Unsubscribe any time.

Leave a Comment